Define lock-inrange, capture range, and Pullintime of a PLL 

1 Answer

0 like 0 dislike
by

*The range of frequencies over which the PLL can maintain lock with the incoming signal is called the lockin range or trackingrange.
*The range of frequencies over which the PLL can acquire lock with an input signal is called the capture range.
*The total time taken by the PLL to establish lok is called pullintime.It depends on the initial phase and frequency differencebetween the two signals as well as on the overall loop gain and loop filter characteristics.